INTRODUCTIONThis is an advance therapeutic Ultrasonic therapy device produce sound waves of 1 MHz frequency used to stimulating the tissue beneath the skin's surfaces, the high frequency massage (stimulation effect) penetrates up to 5" below the skin surface and the effect like micro massage affects very small molecules and membrane cells of tissue in the body and actually causes them to move one place to another and vibrate them at their own place and get them heat up. The continuous high frequency penetration into the cells and molecules results the thermal damages therefore the method of intermitted cycle penetration energy in the better way relief the pain. It is way of frequency modulation in the pattern of high frequency or low frequency. It comes in penetration ON and penetration OFF.
The unit is absolutely compact lightweight device, designed with micro-controller based electronic solid state technique and assembled in powder coated metal chassis, very variable and convenient for clinical use, comfortable for visiting consultants, long running use and personal as well as professional purpose. Insure, before to use this high frequency generator for the treatment to
the patient, the condition and disease for which the treatment is being after to the particular area of the patient should be properly diagnosed by an expert therapist, the treatment may be given.
advanced featureThe unit is designed with latest technology, which comprises the following features:
DISPLAY:All modes treatment timer and intensity displays are provided at the front panel, including LED indicator for easy visibility of friendly use for selected operational mode. The mains ON/OFF switch and transducer socket are provided at front.
USER FRIENDLY OPERATION:The modes of operation, which are provided at front panel, can be selected by the knob and the mode of use will be identified by different LED indicators and time and intensity level will be displayed by LED at front.
MONO FREQUENCY OPERATION:This unit has a 1 MHz frequency generator with transducer head for deep penetration into the tissue and healing the lesion muscle approx 5" area from the surface where applied the high frequency energy and the intensity can be applied as the required area and treated by approx 2.5" dia meter transducer lead.
CONTINUOUS AND PULSE MODE APPLICATION:A continuous transmission of frequency and carried power energy produced into the tissue, efficiently absorbed by portion are connected heat, accelerate the heating and extensively increase the collagen, thus the stretching in stiffness is easier. Athermal effect (Pulse Mode) energy generation is adopted to avoid the tissue from the complications due to the thermal effects or ultrasound producing into the tissue at all.
Cavitations behavior can lead to the formation of highly reactive free radicals although free radicals are produced by cells naturally which are removed by free radicals scavengers, excess production of natural free radicals scavenger system could however be damaging and decrease of intensity cause cavitations use of continuous some time damage the tissue cells due to the excessive energy constantly produced into the tissue and use of pulse wave forms of ultrasound increase the collagen synthesis 30% against the 20% of continuous wave form with the same power ratio. Biological effect related cavitations and micro mass age cells degramulations change on cells membranes functions, increase the level of intracellular calcium, fibroblast activity stimulation resulting, increased protein synthesis, neoangiogenisis collagens elastic tension with those effects more pronounced with pulse ultrasound.
INTENSITY:The power energy produced, unit of power intensity is w/cm’ to 3.5w/cm’ and the diameter area of the transducer is playing significant role for the intensity transmission to the area to be applied for treatment similarly when applied in pulse mode, different pulse modulations are provided and the power intensity reduced in similar ratio.
AUDIO INDICATION:As the treatment time gets over all set parameters becomes Reset '0' condition for further implementations and an audio indication start giving by 33er.
OPERATING INSTRUCTIONSThis unit is designed with latest technology with safety of patient and the user both even it is recommended by the producer (company) before to be used always check the proper functionality of the unit then apply to the patient for treatment.
* The main line cord should be properly attached to socket provided in the backside of the unit through a proper voltage stabilizer.
* And the transducer head lying on the hanger by right side of the unit should be properly attached to the socket.
* A digital timer can be selected for desired treatment and after completion of treatment time an audio alarm switched ON and
controller cuts off the delivery of power output.
* The mode of application can be selected thereafter either in continuous or pulsed mode delivery of power along with different
pulse modulations per second.
* Pulse mode selection is 1 pulse per second to pulse per second available which can be selected as the requirement of the treatment recommended.
* Power level 0.1w/cm’ to maximum 3.5w/cm’ depending upon the area to be treated and the condition of the disease.
* A good quality conductive jelly should be applied for treatment on the area where the treatment has to be given for better performance on the unit.
* Press START/STOP (S/S) switch after selecting all the parameters.
* After completion of treatment as selected for prescribed time and dose, the transducer head should be properly cleaned and put on the hanger lying on one side of the unit.
* Always the machine should be switch OFF from the mains after completion of treatment time.
TECHNICAL DETAILS
Model : Ultrasonic Therapy Unit
Operating Modes : Continuous/Pulse Mode
Operating Frequency © 1MHz
Output : 15 Watts max. in Continuous Mode & 21
Watts max. in Pulse Mode
Ultrasonic Power Density : Up to 3.5 Watts/Sq cum
Treatment Time : 0to99 Minutes
Power Supply © 190-220Volts 50 W
WHAT IS TENS: TENS is a short form for Transcutaneous Electrical Nerve Stimulation. The T.E.N.S generates electrical impulses that are sent through electrodes placed over nerve centers. The various pulses employed by TENS can block pain signals normally sent to the brain through nerve fibers, thereby interrupting the brain's awareness of pain. The TENS may activate the release of endorphins. These are chemicals in the control system by the body to suppress pain naturally. It is no longer necessary for many people to endure chronic or constant pain. The use of TENS usually improves pain management significantly. TENS is safe, non-invasive, drug free, non addictive and has no side effects The TENS can reduce the need for pain narcotics and drugs Federal law restricts these devices to sale by or on the order of a physician. TENS is a DA regulated non-narcotic pain relief device.
HOW DOES TENS WORK: TENS work by two different methods High frequency TENS, 15 based on the theory that continuous mild electrical activity blocks the pain signal travelling to the brain, 1 the pain signal does not get through to the brain, the pain is not felt. The second way TENS work s by stimulating the body s own natural pain control mechanism. Low frequency or short bursts of electrical activity causes the body to release its own pain relieving substance, called endorphins.
HOW THE TENS PAIN CONTROL IS WORK: Pain’s is the body's warning system It is a way of letting an individual knows that something is wrong TENS is a safe non-invasive drug free method of pain management. It relieves pain by sending small electrical impulses through electrodes placed on the skin to underlying nerve fibers. TENS is believed to work by two different mechanisms. First, electrical stimulation of the nerve fibers can block a pain signal from being carried to the brain. If the signal is blocked, pain is not perceived Secondly, the body has its own mechanism for suppressing pain. It does this by releasing natural chemicals called endorphins in the brain which act as analgesies. TENS may activate this mechanism. By effectively managing pain without drug. TENS allows many people with chronic pain conditions to resume daily activity. You cannot strain or sprain your muscles by overworking them with your electronic muscle stimulator system because the feeling is more like a pleasant tingling sensation than a shock or jolt.
IMPORTANT
Its most important to check that the main power line through which the unit is to be used. It should be 220 Volts 50Cycles AC.
CAUTIONS: No nylon Silk, Jari, Terylene, Jersy should cover the part to be treated.
OPERATING INSTRUCTION
- Connect one end of main cord to the socket on the back of the machine and the other end with 2 pin plug to the main line socket.
- It is advisable to give moderate comfortable intensity to the patient.
- Connect the output wire to the OUTPUT socket provided on the unit.
- Set the treatment timer.
- Set the mode with the help of switches located on the front of the panel.
- Fix the electrode with the help of belts provided with the unit.
- Increase the output gradually and slowly.
- Output given to the patient is displayed on the front panel.
- If you want to change the treatment mode please close the intensity and change the mode switch and open the intensity knob.
- In case machine stops working and ON/OFF switch does not glow even when the timer is in on position, switch off the machine take out the main line from the back of the unit, take the fuse located in the back of the unit and check the fuse and if the fuse is black or the wire in the fuse is broken then replace the fuse.
TECHNICAL SPECIFICATION* Output Channel : 2Channel
* Frequency : 2-125Hz
* Timer : 0-99 Min
* Power Input : 220V/50Hz